Product Features
• Support 68-channel cell temperature sampling and 64-channel passive balancing. 1 isolated RS485 channel and 1 isolated CAN channel.
• Support CAN2.0 protocol, compliant with ISOll898-2 2016 standard and communication with the BCU.
• Local storage of system data, support for local and online program upgrade.
Product Specifications
Operating Conditions
|
Power Supply |
Power Supply Voltage |
9V to 30V |
|
Rated Power Consumption |
≤600mW |
|
|
Operating Environment |
Operating Temperature |
-20°C to +65°C |
|
Storage Temperature |
-40°C to +125°C |
|
|
Relative Humidity |
5% to 95% RH |
|
|
Environmental Pressure |
80kPa to 110kPa |
|
|
Altitude |
0m to 2000m |
Basic Functions
| Cell Voltage Sampling | Sampling Range | 0V to 5V |
| Number of Sampling Channels | 64 | |
| Sampling Accuracy | ≤3mV | |
| Sampling Resolution | 1mV | |
| Sampling Rate | Refresh all every 50ms | |
| Electrical Isolation | 5000Vdc/3536Vac | |
| Cell Temperature Sampling | Sampling Range | -40°C to +125°C |
| Number of Sampling Channels | 68 | |
| Sampling Accuracy | Accuracy ≤ 1°C if -20°C ≤ T ≤ +65°C | |
| Accuracy ≤ 2°C if -40°C ≤ T < -20°C or +65°C < T ≤ +125°C | ||
| Sampling Resolution | 0.1℃ | |
| Sampling Rate | Refresh all every 1s | |
| Electrical Isolation | 5000Vdc/3536Vac | |
| Cell Balancing | Passive Balancing Current | 120mA (internal balancing resistance 30R) |
| Simultaneous Activation of Balancing Channels | All can be activated at the same time | |
| Balancing Temperature Rise | <45℃ | |
| Balancing Duration per Command | 1s | |
| IO Port | 2-Channel Bidirectional 10 Port | Supports bidirectional blind insertion |
| Reading Level Range | 0V to 30V | |
| Controls | Input/ Output | |
| Digital Signal Input Detection (1-Channel) | Reading Voltage Range | 0V to 30V |
| High Level Range | 3V to 30V | |
| Low Level Range | 0V to 0.7V | |
| DO Output | 1-Channel PWM Operating Frequency | Default 25 KHz, adjustable |
| 1-Channel PWM Duty Cycle | 0% to 100% | |
| 1-Channel Low-side Output | 1.5A driving capability |
Communication Function
|
Communication Function |
CAN Communication |
Support 1 isolated CAN channel for communication with the BCU |
|
CAN Communication Speed |
250 KB/s |
|
|
RS485 Communication |
Supported 1 isolated RS485 communication channel |
Diagnostics
|
Diagnostics |
Module Diagnostics |
A comprehensive diagnosis function that conducts tests on components such as voltage, temperature, communication, clock, and memory after power-on to ensure the proper operation of the module |
Parameter Settings
|
Configurable Parameters |
Personalized Configuration |
Parameters can be configured using the host computer/display control interface based on customer requirements and the characteristics of the battery |
Dimensions
|
Physical Dimensions |
LxWxH |
343mm×108.5mm×32mm |
Hot Tags: battery management system bmu, China battery management system bmu manufacturers, suppliers, factory, cloud energy interoperability, backup generator alternative, digital energy industry trends in the cloud, cloud energy load balancing, hybrid power supply, wireless charging power station